TCM CombiM Transcutaneous monitor

Product code: 903-111

The TCM CombiM Transcutaneous monitor configuration is designed specifically for neonatal and pediatric intensive care needs. It provides continuous, reliable, accurate, non-invasive and real-time transcutaneous tcpO2 and tcpCO2 information and comes with a range of high performing sensors.

Manufacturer: Radiometer Warranty: 12 luni Tags: tcpo2 , tcm , transcutanat , monitor , tcpco2


For more information please contact us at telephone number: +40-726 30 08 11.

Online assistance +40 21 332.76.31

Details about TCM CombiM Transcutaneous monitor

The tcpO2 measurement, a differentiating feature of the TCM CombiM monitor, is a crucial parameter for patients in neonatal intensive care to avoid the risk of hyperoxia and its effects (eg. retinopathy in preterm babies). Indeed for high oxygenation rate, where SpO2 is not any more accurate, tcpO2 carries on providing a precious information concerning oxygenation of the tissue.
The TCM CombiM monitor combines an enhanced ready-to-use function with a unique gold-plated sensor technology in the tc Sensor 84 and tc Sensor 54, making it highly reliable, stable and robust. Real-time trending of measured parameters is displayed ensuring fast and immediate clinical intervention to critical changes.
The TCM CombiM monitor utilizes various communication protocols to interface with any patient monitoring system and PC.

Specifications

Hardware
Computer specifications
CPU: AMD ETX LX800, 500 MHz (Pentium Class)
RAM: 128 MB
Software platform: Windows CE 5.0
Startup time: max. 1 min
Display
Screen: 6.5 color touch TFT, full VGA (640 x 480)
Display options: normal view (numeric), trend table, trend curve
Display update period: every 2 seconds
Operating conditions
Operating environment: 12-28 °C
Built-in barometer:
Range: 375-825 mmHg
Accuracy: ±5 mmHg
Power: 100-240 V, 50-60 Hz, 70 VA (max.)
Built-in battery:
Rechargeable Pb battery
Typical operating time: 1 hour per charge at 25 °C
Interface connections
Serial output: EIA232 (RS232)
Analog output: 0-1000 mV
Printer output: USB 2.0 (compliant with USB 1.1)
Printer protocol: HP PCL3
Printer reports: trend table, trend curve
Data protocol: VueLink and Monlink

Software
Measuring range
Transcutaneous carbon dioxide tension/tcpCO2: 5-200 mmHg
Transcutaneous oxygen tension/tcpO2: 0-800 mmHg
Sensor heating power: 0-1000mW
Site timer
Indication of remaining measuring time
Measuring time elapsed: clock triggers an alarm and sensor temperature is off
Calibration
Automatic calibration
Calibration gas: 7.5% CO2 and 20.9% O2, balanced N2
Integrated calibration chamber
Alarm level
Alarm sound: high 83 dBA / low 65 dBA
Alert tone: high 73 dBA / low 58 dBA
Patient data storage
Up to 48 hours of measuring data in 2-sec data intervals
Reviewing trends on screen
Download of stored patient data to PC, printer or memory stick
Dimensions
TCM monitor 30.8 cm x 23 cm x 16 cm; weight 4 kg
CombiM module 14.5 cm x 14.8 cm x 10.7 cm; weight 0.575 kg

Sensor specifications

Measuring principle
tc Sensor 54: Stow-Severinghaus-type pCO2 sensor
tc Sensor 84: Stow-Severinghaus-type pCO2 combined with Clark-type pO2 sensor
Sensor remembraning requirements
Every 14 days
Built-in alert when sensor needs remembraning
Protected membrane
Sensor temperature
Selectable between 37.0-44.0 °C in steps of 0.5 °C
Reliable safe control by two independent circuits
Accuracy: ±0.2 °C
Automatic temperature off when site time is elapsed
Sensor memory
Sensor has a built-in memory for calibration values, remembraning date and other sensor data
Sensor performance (in vitro)
tc Sensor 54
Conditions: sensor temperature of 42.0 °C, calibration interval: 12 h
tcpCO2:
Response time (10-90%): ≤ 60sec
Drift: ≤ 0.5%/h
Linearity: at 1 and 10% CO2: better than 1 mmHg
at 33% CO2: better than 3 mmHg
tc Sensor 84
Conditions: sensor temperature of 44.0 °C, calibration interval: 4 h
tcpCO2:
Response time (10-90%): ≤ 60sec
Drift: ≤ 1%/h
Linearity: at 1 and 10% CO2: better than 1 mmHg
at 33% CO2: better than 5 mmHg
tcpO2:
Response time (10-90%): ≤ 25 sec
Drift: ≤ 1%/h
Linearity: at 0% O2: better than 1 mmHg
at 21% O2: better than 3 mmHg
at 50% O2: better than 5 mmHg
at 90% O2: better than 25 mmHg
Interference by anesthetic gases (in vitro)
tcpCO2:
75% N2O, 2% Halothane, 2% Enflurane and 2% Isoflurane: negligible
tcpO2:
75% N2O:<10mmHg
2% Halothane: approx. 200 mmHg
2% Enflurane and 2% Isoflurane: negligible
Sensor dimensions
Diameter: 15 mm
Height: 8 mm
Weight: 3 g
Sensor cable length: 3 m, shielded, flexible, polyurethane coated